SENSORS FOR WATER INGRESS DETECTION
|
SENSORS will be used for detection of water levels. Pressure sensors are provided for cargo holds and tanks. Level switches are provided for dry/void spaces.
The sensors have to be installed at aft bulkhead of cargo holds. One sensor/cargo hold is sufficient when the sensor is installed centreline otherwise two sensors have to be installed one PS; one SB.
For dry spaces is one level switch installed at aft wall sufficient.
The pressure sensors of types HCG 2011; HCG 2031 and HCG 4010 are provided for installation in cargo holds and spaces for detection of water level in corresponding compartments.
|
 |
THE Sensors are executed in protection class of IP68 in accordance with IEC 60529 as specified in SOLAS regulations. The sensors are type approved for operation in all cargo/water mixture.
The sensors were tested in following cargo/water mixture:
- Iron ore particles and water
- Grain particles and water
- Coal particles and water
- Aggregate (sand) particles and water
|
 |
|